The guideline and the standard are read in the copies Public.Resource.Org keeps. A table row is printed cell after cell, the way the PDF holds it. Wikipedia’s text is used under the Creative Commons Attribution-ShareAlike 4.0 licence. Each quotation is cut from a saved copy and checked again at every build.
The road guideline
Indian Roads Congress, on designing and laying block paving.
IRC:SP:63-2018, Guidelines for the Use of Interlocking Concrete Block Pavement (first revision)
- 8.7 Establishing the Laying Pattern
Cut units less than 50 mm minimum dimension should not be used, as these are difficult to cut accurately and can be dislodged under traffic.
Cited on Paver block calculator, Patterns, About
- 8.7 Establishing the Laying Pattern
Where space does not permit use of a larger segment, use premixed concrete or a sand-cement mortar instead.
Cited on Paver block calculator, Patterns
- 6.4 Dimensional and other Requirements of Paving Blocks
the length of a paving block should ordinarily be not greater than twice the mean width; the thickness is a minimum of 60 mm; the maximum length generally not exceeding 280 mm; the width generally is in the range 75 to 140 mm with a chamfer in the range 3-5 mm.
Cited on Paver block calculator, Thickness and grade
- 4.4 Sand Bedding and Jointing
The joints are normally 2 - 4 mm wide.
Cited on Paver block calculator
- Table 1, Design Catalogue for Pavement Thickness: the first row, cell after cell
• Cycle Tracks, Block Thickness 60 mm 60 mm Pedestrian Footpaths Sand Bed 30±5 mm 30±5 mm M-30 Granulated Subase 200 mm 200 mm
Cited on Paver block calculator, Layers, About
- Table 1, Design Catalogue for Pavement Thickness: the second row, cell after cell
• Commercial Traffic Block Thickness 60-80 mm 60-80 mm Axle Load Repetitions Sand Bed 30±5 mm 30±5 mm less than 10 msa WBM/WMM Base 250 mm 250 mm M-40 • Residential Streets Granular Sub-base 200 mm 250 mm
Cited on Paver block calculator, Layers
- Table 1, Design Catalogue for Pavement Thickness: the third row, cell after cell
• Commercial traffic Block Thickness 80-100 mm 80-100 mm Axle Load Repetitions 10-20 msa Sand Bed 30±5 mm 30±5 mm • Collector Streets M-40 Industrial Streets, Bus WBM/WMM Base 250 mm 250 mm and Truck Parking Areas Granular Sub-base 200 mm 250 mm
Cited on Paver block calculator, Layers
- Table 1, Design Catalogue for Pavement Thickness: the fourth row, cell after cell
• Commercial traffic Block Thickness 100-120 100-120 (Container yard and Sand Bed 30 ±5 mm 30 ±5 mm see ports) Axle Load WBM/WMM Base 250 mm 250 mm Repetitions or 20-50 msa WBM/WMM Base 150 mm 150 mm M-50 and DLC over it* 100 mm 100 mm • Arterial Streets Granular Sub-base 200 mm 250 mm
Cited on Paver block calculator, Layers
- 4.3 Block Thickness
For light traffic, such as, pedestrians, motor cars, cycles, etc., a block thickness of 60 mm is adequate
Cited on Paver block calculator, Thickness and grade
- 4.3 Block Thickness
for medium traffic, a thickness of 80 mm is generally used
Cited on Paver block calculator, Thickness and grade
- 4.3 Block Thickness
for heavily trafficked roads, blocks of the thickness 100-120 mm are used.
Cited on Paver block calculator, Thickness and grade
- 8.6 Bonds or Patterns of Laying Blocks
popular bonds commonly adopted for block paving are: (i) Stretcher or running bond (ii) Herringbone bond (iii) Basket weave or parquet bond
Cited on Paver block calculator, Patterns
- 4.3 Block Thickness
Thick blocks are best suited where high volumes of turning movements are involved.
Cited on Thickness and grade
- 4.3 Block Thickness
all blocks should be of the same thickness, with a maximum allowable tolerance limits of ± 2 mm.
Cited on Thickness and grade
- 4.3 Block Thickness
variations in length and width of blocks should be limited to ± 2 to ± 3 mm
Cited on Thickness and grade
- 6.4 Dimensional and other Requirements of Paving Blocks
the average water absorption in a block should not exceed 5 per cent
Cited on Thickness and grade
- 2.2.2 Limitations
Concrete block pavements cannot be used for high speed facilities.
Cited on Thickness and grade
- 1 Scope, 1.2
The use of interlocking concrete block pavement is not recommended for Expressways, National Highways, State Highways and Major District Road.
Cited on Thickness and grade
- 2.2.2 Limitations
A very good attention to pavement drainage is needed because the water can seep through the joints.
Cited on Thickness and grade
- 3 Types and Shapes of Blocks
Category A: Dentated units are designed to key into each other on all four faces
Cited on Patterns
- 3 Types and Shapes of Blocks
blocks are generally capable of being laid in Herringbone Bond Pattern
Cited on Patterns
- 3 Types and Shapes of Blocks
Category B: These blocks are dentated on only two sides.
Cited on Patterns
- 3 Types and Shapes of Blocks
exceptions, these blocks can only be laid in Stretcher Bond
Cited on Patterns
- 3 Types and Shapes of Blocks
Category C: These are not dentated type but depend on dimensional accuracy for interlocking effect.
Cited on Patterns
- 3 Types and Shapes of Blocks
These blocks can be laid only in a stretcher bond.
Cited on Patterns
- 8.5 Laying of Blocks
Normally, laying should commence from the edge strip and proceed towards the inner side.
Cited on Patterns
- 8.5 Laying of Blocks
laying should proceed in one direction only, along the entire width of the area to be paved.
Cited on Patterns
- 8.5 Laying of Blocks
On a sloping site, start from the lowest point and proceed uphill on a continuous basis
Cited on Patterns
- 8.7 Establishing the Laying Pattern
full blocks should be used; only subsequently, cutting and in-filling at edges be permitted.
Cited on Patterns
- 8.7 Establishing the Laying Pattern
the joint width specification (2 to 3 mm) should be checked in the first few square metres
Cited on Patterns
- 8.7 Establishing the Laying Pattern
chalked string lines, at about 5 m intervals.
Cited on Patterns
- Table 1, note 2
Granular sub-base should have at least 150 mm layer at the bottom.
Cited on Layers
- 4.4 Sand Bedding and Jointing
A layer thickness of 30 ± 5 mm is found to be satisfactory.
Cited on Layers
- 8.4 Placing and Screeding of Bedding Sand
The thickness of the sand bed after compaction should be in the range of 30 ± 5 mm, whereas, in the loose form it can be 30 to 50 mm.
Cited on Layers
- 4.4 Sand Bedding and Jointing
The sand bed should not be too thick lest it would be difficult to control the surface level of the blocks.
Cited on Layers
- 4.4 Sand Bedding and Jointing
The sand used should be free from plastic clay and should be angular type.
Cited on Layers
- 8.4 Placing and Screeding of Bedding Sand
Bedding sand should not be used to fill-up local depressions on the surface of a base or sub-base.
Cited on Layers
- 6.5.2 Joint filling sand
The gaps in between two paving blocks (typically about 2-3 mm wide) need to be filled by sand, relatively finer than the bedding sand.
Cited on Layers
- 6.5.2 Joint filling sand
it is not advisable to use cement in the joint filling sand
Cited on Layers
- 6.5.2 Joint filling sand
The joint filling sand should be as dry as possible
Cited on Layers
- 8.8.4 Joint filling
Unfilled or partially filled joints allow blocks to deflect, leading to loose blocks
Cited on Layers
- 8.8.5 Opening to traffic
Until all the joints are completely filled, no traffic should be permitted over the block pavement.
Cited on Layers
- 4.6 Edge Restraint Blocks and Kerbs
The tendency to move sideways has to be counteracted at the edges by special edge blocks and kerbs.
Cited on Layers
- 4.6 Edge Restraint Blocks and Kerbs
to have at least a 28 day compressive strength of 30 MPa
Cited on Layers
- 8.8.3 Compaction
at least two passes of the vibratory plate compactor are needed.
Cited on Layers
- Table 1, note 4
If the subgrade soil has a CBR of less than 5%, it should be improved by suitable stabilisation technique to bring the CBR value to 5%.
Cited on Layers
- 9.2 Initial Maintenance
After about a week of laying the blocks there is a need to inspect the surface to check for any loss of sand at joints.
Cited on Layers
- 5.1 Suggested Design Procedure
It is recommended that the catalogue of design as given in Table 1 may be used.
Cited on Layers
The standard for the block
Bureau of Indian Standards. The saved copy is a scan read by machine.
IS 15658:2006, Precast Concrete Blocks for Paving: Specification
- Table 1, row i: the cells in order
M-30 30 Non-traffic 50 Building premises, monument premises,
Cited on Thickness and grade
- Table 1, note 1
Non-traffic areas are defined as areas where no vehicular traffic occurs.
Cited on Thickness and grade
- Table 1, row ii: the cells in order
M-35 35 Light-traffic 60 Pedestrian plazas, shopping complexes
Cited on Thickness and grade
- Table 1, note 2
Light-traffic is defined as a daily traffic up to 150 commercial vehicles exceeding 30 kN laden weight
Cited on Thickness and grade
- Table 1, row iii: the cells in order
M-40 40 Medium-traffic 80 City streets, small and medium market
Cited on Thickness and grade
- Table 1, note 3
Medium traffic is defined as a daily traffic of 150-450 commercial vehicles exceeding 30 kN laden weight
Cited on Thickness and grade
- Table 1, row iv: the cells in order
M-50 50 Heavy-traffic 100 Bus terminals, industrial complexes, mandi
Cited on Thickness and grade
- Table 1, note 4
Heavy traffic is defined as a daily traffic of 450-1500 commercial vehicles exceeding 30 kN laden weight
Cited on Thickness and grade
- Table 1, row v: the cells in order
M-55 55 Very heavy-traffic 120 Container terminals, ports, docks yards,
Cited on Thickness and grade
- Table 1, note 5
Very heavy-traffic is defined as a daily traffic of more than 1500 commercial vehicles exceeding 30 kN laden weight
Cited on Thickness and grade
- Table 1, title
Recommended Grades of Paver Blocks for Different Traffic Categories
Cited on Thickness and grade
Definitions
What a bond is, in the words of the article on it.
Herringbone pattern
- Opening
The herringbone pattern is an arrangement of rectangles used for floor tilings and road pavement
Cited on Patterns
Pavers (flooring)
- Block paving
This pattern is the strongest of the block paving bonds as it offers the most interlock
Cited on Patterns